PRODUCTS & SOLUTIONS

    SL 940

    Dimensions

    useful pitch mm. 940

    height 25 mm.

    Thickness

    from mm 0,6 to mm 1

    EPD certification (CAM)

    For more information on CAM certification, contact the technical / commercial department.

    Materials

    Galvanized steel, coated or laminated; stainless steel, copper:
    - steel in compliance with the UNI EN 10147 Fe E 250 G type, available in hot galvanized with "sendzimir" process, pre-painted or plasticized galvanized.
    - Aluminum alloy 3103 H16 conforming to the UNI 9003/3 Standard or according to UNI 10372, available natural or pre-painted.
    - AISI 304 stainless steel, 2B finish, compliant with UNI 10372 Standards.
    - CORTEN.
    - Copper conformity with standards UNI EN 1172 - UNI 10372.

    Protective treatments for external support available

    polyester outdoor coating, silicone polyester, PVDF, thermoplastic class A

    LOADS TABLE

    PITCH BETWEEN SUPP.(m)
    SHEET TICKNESS(mm)
    MATERIAL
    MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION *
    Panel
    Thickness
    (mm)
    MaterialSheet
    thickness
    (mm)
    Pitch 'L' in meters between the supports
    0,80 1,00 1,25 1,50 1,75 2,00 2,25 2,50 2,75 3,00
    0ACCIAIO0,6 1052 626 320 185 117 78 55 40
    MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION *
    Panel
    Thickness
    (mm)
    MaterialSheet
    thickness
    (mm)
    Pitch 'L' in meters between the supports
    0,80 1,00 1,25 1,50 1,75 2,00 2,25 2,50 2,75 3,00
    0ACCIAIO0,6124080051230819513092675039

    Insights on the test report

    (Note) The report test given, is provided for information purposes only. Values and formulas should not be used to determine or calculate the flow rate of the panel. It is the responsibility and care of the customer and/or designer to draft appropriate calculations with specific reference for individual uses. The thicknesses and quality of steel defined in the report test above, does not represent a standard of product as the combination of thicknesses and materials is determined by the customer according to their technical requirements, therefore the customer and/or the designer are required to specify thickness, quality and type of materials that the producer will use in the construction of the panels.

     

    * deflection = 1/200 L